ojs2 has produced an error Message: WARNING: mkdir(): Permission denied In file: /var/www/html/ojs246_old/lib/pkp/classes/file/FileManager.inc.php At line: 306 Stacktrace: Server info: OS: Linux PHP Version: 5.6.33-0+deb8u1 Apache Version: Apache/2.4.10 (Debian) DB Driver: mysql DB server version: 5.7.27
ojs2 has produced an error Message: WARNING: assert(): Assertion failed In file: /var/www/html/ojs246_old/plugins/generic/usageStats/UsageStatsPlugin.inc.php At line: 308 Stacktrace: Server info: OS: Linux PHP Version: 5.6.33-0+deb8u1 Apache Version: Apache/2.4.10 (Debian) DB Driver: mysql DB server version: 5.7.27
Determination of Parabens in Cosmetic Samples by Sub-Minute High-Performance Liquid Chromatography Method | Sirichai | งดใช้ระบบ 3-31 กค 66 Burapha Science Journal

Determination of Parabens in Cosmetic Samples by Sub-Minute High-Performance Liquid Chromatography Method

Somsak Sirichai, Khajadpai Thipyapong

Abstract


          This research was developed to a sub-minute separation method and simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples by high-performance liquid chromatography coupled with photodiode array detector for simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples. Parabens were separated on a Chromolith column using gradient elution with acetonitrile and water, the flow rate of 1.3 mL  min-1 and detected at 254 nm.  Under the optimal conditions, the separation was completed in less than 1 min. Calibration curves for standard solution of parabens  were linear over the concentration range of 0.50-10.0 mg L-1 with R2 greater than 0.999. The limits of detection and limits of quantification of parabens were found between 0.12-0.15 mg L-1, and 0.40-0.45 mg L-1, respectively. The accuracy in terms of percent recovery of parabens was in the range of 97.2-102.6. Repeatability and reproducibility of the method were in the range of 1.11-1.50% and 2.30-2.70%, respectively. The development method could be applied to the simultaneous determination of parabens in cosmetic samples.

 

Keywords:  high-performance liquid chromatography, sub-minute, paraben, cosmetic


Full Text:

PDF

References


Borremans, M., Van-Loco, J., Roos, P., & Goeyens, L. (2004). Validation of HPLC analysis of 2-

phenoxyethanol, 1-phenoxypropan-2-ol, methyl, ethyl, propyl, butyl and benzyl 4-hydroxybenzoate

(parabens) in cosmetic products, with emphasis on decision limit and detection capability.

Chromatographia, 59, 47–53.

Cheng, Y., Wang, C., Chen, Y., & Wu, S. (2012). Large volume sample stacking with EOF and sweeping in CE

for determination of common preservatives in cosmetic products by chemometric experimental design. Electrophoresis, 33, 1443–1448.

Cruces-Blanco, C., Segura-Carretero, A., Gálvez-Mata, L., & Fernández-Gutierrez, A. (2001). Simultaneous

determination, by capillary zone electrophoresis, of multiple components of different industrial products. Chromatographia, 53, 414– 418.

Darbre, P.D., Aljarrah. A., Miller, W.R., Coldham, N.G., Sauer, M.J., & Pope, G.S. (2004). Concentrations of

parabens in human breast tumors. Journal of Applied Toxicology, 24, 5-13.

Dobbins, L.L., Usenko, S., Brain, R.A., & Brooks, B.W. (2009). Probabilistic ecological hazard assessment of

parabens using daphnia manga and pimephales promelas. Environmental Toxicology and Chemistry, 28, 2744-2753.

ICH Harmonised Tripartite Guideline Q28 Validation of analytical procedures: text and methodology Q2(R1),

November 2005.

Gao, W., Gray, N., Heaton, J., Smith, N.W., Jia, Y., Legido-Quigley, C. (2012). UV gradient combined with

principal component analysis: Highly sensitive and specific high performance liquid chromatography analysis of cosmetic creams. Journal Chromatography A, 1228, 324–328.

Gao, W., & Legido-Quigley, C. (2011). Fast and sensitive high performance liquid chromatography analysis of

cosmetic creams for hydroquinone, phenol and six preservatives. Journal of Chromatography A, 1218, 4307–4311.

Gagliardi, L., de Orsi, D., Manna, L., & Toneli, D. (1997). Simultaneous determination of antioxidants and

preservatives in cosmetics and pharmaceutical preparations by reversed phase HPLC. Journal of Liquid Chromatography, 20, 1797-1808.

Huang, H., Huang, I., & Lin, H.Y. (2006). Separation of parabens in capillary electrochromatography using

poly(styrenedivinylbenzene-methacrylic acid) monolithic column. Journal of Separation Science, 29, 2038–2048.

Notification of the Ministry of Health: Preservatives in Cosmetics Retrieved May 11, 2017, from

https://www.thaicosmetic.org/documents/moph-announcement-preservative.pdf (in Thai)

Sánchez-Prado, L., Llompart, M., Lamas, J.P., García-Jares, & C., Lores, M. (2011). Multicomponent

analytical methodology to control phthalates, synthetic musks, fragrance allergens and preservatives

in perfumes. Talanta, 85, 370–379.

Rodford, R. (1997). Safety evaluation of preservatives. International Journal of Cosmetic Science, 19,

-290.

Wang, P.G., & Zhou, W. (2013). Rapid determination of parabens in personal care products by stable isotope

gas chromatography-tandem mass spectrometry with dynamic selected reaction monitoring. Journal of Separation Science, 36, 1781–1787.

Youngvises , N., Chaida, T., Khonyoung , S., Kuppithayanant, N., Tiyapongpattana, W., Itharat, A., &

Jakmunee, J. (2013). Greener liquid chromatography using a guard column with micellar mobile

phase for separation of some pharmaceuticals and determination of parabens. Talanta, 15, 350–359.

Zgota-Grzeskowiak, A., Werner, J., Jeszka-Skowrona, M., & Czarczynska-Goslinska, B. (2016). Determination

of parabens in cosmetic products using high performance liquid chromatography with fluorescence detection. Analytical Methods, 8, 3903-3909.

Zhang, Q., Lian, M., Liu, L., & Cui, H. (2005). High-performance liquid chromatographic assay of parabens in

wash-off cosmetic products and foods using chemiluminescence detection. Analytica Chimica Acta, 537, 31–39.


Refbacks

  • There are currently no refbacks.